Froped 009

Side-by-side product pages for the BHT-009 heating thermostat and BAC-009 fan-coil thermostat. Use this page to compare features, specs and photos — identical design and layout as your 006 pages.

Jump to comparison
9
Choose the right 009 model
Heating thermostat vs fan-coil thermostat — specs, photos, gallery.

Froped BHT-009 (Heating Thermostat)

Knob • Heating • Wi-Fi
BHT-009 front
Reliable heating thermostat for floor, boiler and electric systems.
Intuitive interface, accurate control and Tuya-compatible smart features.
Back image:
BHT-009 back

Specifications

Power Supply
95–240 VAC, 50–60 Hz or 24V DC/AC, 50–60 Hz
Current Load
5A (water heating, water/gas boiler), 16A (electric heating)
Sensor
NTC3950, 10K
Accuracy
±1 °C
Set Temp. Range
5–35 °C
Room Temp. Range
5–70 °C
Display Temp. Range
5–70 °C
Ambient Temp.
0–45 °C
Ambient Humidity
5–95% RH (Non-Condensing)
Storage Temp.
-5–45 °C
Power Consumption
<1.5 W
Timing Error
<1%
Shell Material
PC + ABS (Fireproof)
Installation Box
86×86 mm Square or 60mm European Round Box
Wire Terminals
Wire 2×1.5 mm² or 1×2.5 mm²
Protection Class
IP20
Buttons
Capacitive Touch Buttons

Easy Installation

Designed to work with standard installation boxes and supports both internal and external sensors.

Smart Control

Wi-Fi enabled for remote scheduling and voice control via common smart platforms.

PDF Preview

Froped BAC-009 (Fan-Coil Thermostat)

Touch • Fan-Coil • Wi-Fi
BAC-009 front
Fan-coil thermostat with multi-mode control and relay outputs.
Supports 2/4-pipe systems, fan speed control and app integration.
Back image:
BAC-009 back

Specifications

Power Supply
95–240 VAC, 50–60 Hz or 24V DC/AC
Fan Relay Amps (Resistive)
5 A
Fan Relay Amps (Inductive)
3 A
Valve Relay Amps (Resistive)
3 A
Valve Relay Amps (Inductive)
1 A
Sensor
NTC3950, 10K
Set Temp. Range
5–35 °C
Accuracy
±1 °C
Display Temp. Range
5–99 °C
Ambient Temp.
0–45 °C
Ambient Humidity
5–95% RH (Non-Condensing)
Storage Temp.
–5–45 °C
Timing Error
< 1%
Power Consumption
<1.5 W
Shell Material
PC + ABS (Fireproof)
Installation Box
86×86 mm square / 60 mm round box
Wire Terminals
Wire 2 × 1.5 mm² or 1 × 2.5 mm²
Protection Class
IP20
Buttons
Capacitive Touch Buttons

Fan-Coil Support

Designed for 2/4 pipe fan-coil units with multiple fan speed control and valve outputs.

Smart Scheduling

Weekly scheduling and remote control through the Tuya ecosystem.

PDF Preview

Direct Comparison

Control
BHT-009: Heating (knob/touch) — BAC-009: Fan-coil (touch)
Connectivity
Both: Wi-Fi (Tuya) — App & voice control
Best for
BHT-009: Underfloor / Boiler / Electric heating — BAC-009: Fan-coil units (2/4 pipe)
Load Handling
BHT-009: 16 A (electric) — BAC-009: Fan/Valve relays 3–5 A
Sensor Options
BHT-009: internal/external probe — BAC-009: NTC sensors
Programming
BHT-009: Basic scheduling — BAC-009: 5+1+1 or 6-period weekly (model dependent)

View Photos

BHT-009
BHT-009 rear
BAC-009
BAC-009 rear